J

J. Opfermann

Total Citations
1,928
h-index
19
Papers
2

Publications

#1 2608.05109v1 Aug 05, 2026

AI-based single-shot structured-light depth reconstruction for real-time laparoscopic surgical guidance

Significance. Accurate intraoperative depth perception is important for autonomous and semi-autonomous robotic laparoscopic surgery. Conventional fringe projection profilometry can achieve millimeter-scale accuracy but often requires multi-shot acquisition, digital-micromirror-device projection, and projector-camera synchronization, complicating integration into compact laparoscopic systems. Aim. To develop a synchronization-free, single-shot depth-sensing platform using a passive LED-illuminated binary mask and a VQ-VAE prior with a custom U-Net depth head. Approach. A compact projection module was coupled to one channel of a dual-channel laparoscope, while the second channel imaged the fringe-illuminated target. A Zivid 3D camera acquired reference depth for 722 paired phantom images. Zivid depth maps were reprojected into the SSLE image frame for supervised training and evaluation. The VQ-VAE encoded each input into a discrete latent representation, and a latent-space U-Net predicted depth without a separate mask-prediction branch. Results. Using a fixed train/validation/test split, the proposed model achieved an MAE of 3.70 mm, AbsRel of 0.0326, delta=1.1 accuracy of 0.962, and delta=1.1^2 accuracy of 0.970. It achieved lower MAE than the dual U-Net MaskNet + DepthNet baseline and outperformed off-the-shelf monocular depth models in MAE, AbsRel, and threshold accuracy. The pipeline operated at 26.0 Hz over 301 consecutive frames on an NVIDIA A100 GPU. Conclusions. The LED-illuminated binary-pattern platform with latent-space depth reconstruction enables synchronization-free, video-rate endoscopic depth estimation. Results demonstrate Zivid-referenced phantom reconstruction without an explicit segmentation stage, while emphasizing the importance of dataset size and SSLE-Zivid calibration accuracy.

M. Kam J. Opfermann Wayne Wonseok Rodgers Xiangyi Le Seonghoon Jang +3
0 Citations
#2 2604.21017v1 Apr 22, 2026

Open-H-Embodiment: A Large-Scale Dataset for Enabling Foundation Models in Medical Robotics

Autonomous medical robots hold promise to improve patient outcomes, reduce provider workload, democratize access to care, and enable superhuman precision. However, autonomous medical robotics has been limited by a fundamental data problem: existing medical robotic datasets are small, single-embodiment, and rarely shared openly, restricting the development of foundation models that the field needs to advance. We introduce Open-H-Embodiment, the largest open dataset of medical robotic video with synchronized kinematics to date, spanning more than 49 institutions and multiple robotic platforms including the CMR Versius, Intuitive Surgical's da Vinci, da Vinci Research Kit (dVRK), Rob Surgical BiTrack, Virtual Incision's MIRA, Moon Surgical Maestro, and a variety of custom systems, spanning surgical manipulation, robotic ultrasound, and endoscopy procedures. We demonstrate the research enabled by this dataset through two foundation models. GR00T-H is the first open foundation vision-language-action model for medical robotics, which is the only evaluated model to achieve full end-to-end task completion on a structured suturing benchmark (25% of trials vs. 0% for all others) and achieves 64% average success across a 29-step ex vivo suturing sequence. We also train Cosmos-H-Surgical-Simulator, the first action-conditioned world model to enable multi-embodiment surgical simulation from a single checkpoint, spanning nine robotic platforms and supporting in silico policy evaluation and synthetic data generation for the medical domain. These results suggest that open, large-scale medical robot data collection can serve as critical infrastructure for the research community, enabling advances in robot learning, world modeling, and beyond.

Ziyun Zhang Jianmin Ji Zhongliang Jiang Yanyong Zhang Hao Chen +208
4 Citations