Shuo Wang
Publications
A report-grounded vision-language foundation model for colonoscopy from 280000 routine reports
Vision-language models remain underused in colonoscopy despite the rich expert descriptions recorded in routine reports. These reports document lesion appearance, size and location but summarise entire procedures rather than caption individual frames, leaving clinical findings only weakly linked to the corresponding images. Here we develop EndoCLIP, a colonoscopy vision-language foundation model trained on 125,756 lesion-level image-text pairs progressively recovered from 280,476 routine colonoscopy records. Across lesion-level image-text retrieval, structured report generation and six multi-centre clinical classification tasks, EndoCLIP outperforms general-purpose and biomedical vision-language encoders in both zero-shot and linear-probe settings. On benign-versus-malignant classification, its linear probe approaches the performance of expert readers in a blinded study involving 12 endoscopists. These results suggest that recovering finding-to-frame correspondence can transform routine documentation into scalable supervision, enabling clinical targets to be specified in language rather than separately annotated for each task.
Development and multi-center evaluation of domain-adapted speech recognition for human-AI teaming in real-world gastrointestinal endoscopy
Automatic speech recognition (ASR) is a critical interface for human-AI interaction in gastrointestinal endoscopy, yet its reliability in real-world clinical settings is limited by domain-specific terminology and complex acoustic conditions. Here, we present EndoASR, a domain-adapted ASR system designed for real-time deployment in endoscopic workflows. We develop a two-stage adaptation strategy based on synthetic endoscopy reports, targeting domain-specific language modeling and noise robustness. In retrospective evaluation across six endoscopists, EndoASR substantially improves both transcription accuracy and clinical usability, reducing character error rate (CER) from 20.52% to 14.14% and increasing medical term accuracy (Med ACC) from 54.30% to 87.59%. In a prospective multi-center study spanning five independent endoscopy centers, EndoASR demonstrates consistent generalization under heterogeneous real-world conditions. Compared with the baseline Paraformer model, CER is reduced from 16.20% to 14.97%, while Med ACC is improved from 61.63% to 84.16%, confirming its robustness in practical deployment scenarios. Notably, EndoASR achieves a real-time factor (RTF) of 0.005, significantly faster than Whisper-large-v3 (RTF 0.055), while maintaining a compact model size of 220M parameters, enabling efficient edge deployment. Furthermore, integration with large language models demonstrates that improved ASR quality directly enhances downstream structured information extraction and clinician-AI interaction. These results demonstrate that domain-adapted ASR can serve as a reliable interface for human-AI teaming in gastrointestinal endoscopy, with consistent performance validated across multi-center real-world clinical settings.