Yueyang Cang
Publications
FeedbackTrack: Visual-Cortex-Inspired Cross-Frame Feedback for Transformer Tracking
Visual object tracking requires effective temporal integration, yet most Transformer trackers still rely on predominantly feed-forward feature extraction. Existing temporal mechanisms typically update templates, prompts, queries, or prediction states, while intermediate representations are rarely reused to modulate corresponding processing stages. We propose \textbf{FeedbackTrack}, a visual-cortex-inspired framework that introduces sparse, group-level layer-aligned cross-frame feedback into pretrained Transformer trackers. Previous-frame intermediate states are detached, cached, and returned to corresponding Transformer groups in the current frame through two lightweight pathways: Query Feedback for token-level query modulation and Gate Feedback for context-dependent feature modulation. FeedbackTrack preserves the original tracking pipeline with only a fixed-size one-frame cache. Across SPMTrack and ARTrackV2, FeedbackTrack consistently improves five backbone configurations on LaSOT and GOT-10k, achieving 83.4 AO and 79.1 AUC with SPMTrack-G while adding less than 1\% parameters. Controlled comparisons show that cross-frame feedback outperforms same-frame modulation by 1.8--3.2 AO points, demonstrating that the gains mainly come from recurrent historical information. Further analysis reveals a non-uniform depth-dependent organization of learned feedback strengths, highlighting the effectiveness of recurrent feedback for Transformer tracking.
Intelligent Pathological Diagnosis of Gestational Trophoblastic Diseases via Visual-Language Deep Learning Model
The pathological diagnosis of gestational trophoblastic disease(GTD) takes a long time, relies heavily on the experience of pathologists, and the consistency of initial diagnosis is low, which seriously threatens maternal health and reproductive outcomes. We developed an expert model for GTD pathological diagnosis, named GTDoctor. GTDoctor can perform pixel-based lesion segmentation on pathological slides, and output diagnostic conclusions and personalized pathological analysis results. We developed a software system, GTDiagnosis, based on this technology and conducted clinical trials. The retrospective results demonstrated that GTDiagnosis achieved a mean precision of over 0.91 for lesion detection in pathological slides (n=679 slides). In prospective studies, pathologists using GTDiagnosis attained a Positive Predictive Value of 95.59% (n=68 patients). The tool reduced average diagnostic time from 56 to 16 seconds per case (n=285 patients). GTDoctor and GTDiagnosis offer a novel solution for GTD pathological diagnosis, enhancing diagnostic performance and efficiency while maintaining clinical interpretability.