H

Haolin Wang

Total Citations
23
h-index
3
Papers
2

Publications

#1 2603.05860v1 Mar 06, 2026

Evolving Medical Imaging Agents via Experience-driven Self-skill Discovery

Clinical image interpretation is inherently multi-step and tool-centric: clinicians iteratively combine visual evidence with patient context, quantify findings, and refine their decisions through a sequence of specialized procedures. While LLM-based agents promise to orchestrate such heterogeneous medical tools, existing systems treat tool sets and invocation strategies as static after deployment. This design is brittle under real-world domain shifts, across tasks, and evolving diagnostic requirements, where predefined tool chains frequently degrade and demand costly manual re-design. We propose MACRO, a self-evolving, experience-augmented medical agent that shifts from static tool composition to experience-driven tool discovery. From verified execution trajectories, the agent autonomously identifies recurring effective multi-step tool sequences, synthesizes them into reusable composite tools, and registers these as new high-level primitives that continuously expand its behavioral repertoire. A lightweight image-feature memory grounds tool selection in a visual-clinical context, while a GRPO-like training loop reinforces reliable invocation of discovered composites, enabling closed-loop self-improvement with minimal supervision. Extensive experiments across diverse medical imaging datasets and tasks demonstrate that autonomous composite tool discovery consistently improves multi-step orchestration accuracy and cross-domain generalization over strong baselines and recent state-of-the-art agentic methods, bridging the gap between brittle static tool use and adaptive, context-aware clinical AI assistance. Code will be available upon acceptance.

Haolin Wang Pengyu Dai Lin Fan Zhipeng Deng Xun Gong +2
1 Citations
#2 2602.07044v1 Feb 04, 2026

PipeMFL-240K: A Large-scale Dataset and Benchmark for Object Detection in Pipeline Magnetic Flux Leakage Imaging

Pipeline integrity is critical to industrial safety and environmental protection, with Magnetic Flux Leakage (MFL) detection being a primary non-destructive testing technology. Despite the promise of deep learning for automating MFL interpretation, progress toward reliable models has been constrained by the absence of a large-scale public dataset and benchmark, making fair comparison and reproducible evaluation difficult. We introduce \textbf{PipeMFL-240K}, a large-scale, meticulously annotated dataset and benchmark for complex object detection in pipeline MFL pseudo-color images. PipeMFL-240K reflects real-world inspection complexity and poses several unique challenges: (i) an extremely long-tailed distribution over \textbf{12} categories, (ii) a high prevalence of tiny objects that often comprise only a handful of pixels, and (iii) substantial intra-class variability. The dataset contains \textbf{240,320} images and \textbf{191,530} high-quality bounding-box annotations, collected from 11 pipelines spanning approximately \textbf{1,480} km. Extensive experiments are conducted with state-of-the-art object detectors to establish baselines. Results show that modern detectors still struggle with the intrinsic properties of MFL data, highlighting considerable headroom for improvement, while PipeMFL-240K provides a reliable and challenging testbed to drive future research. As the first public dataset and the first benchmark of this scale and scope for pipeline MFL inspection, it provides a critical foundation for efficient pipeline diagnostics as well as maintenance planning and is expected to accelerate algorithmic innovation and reproducible research in MFL-based pipeline integrity assessment.

Tianyi Qu Songxiao Yang Haolin Wang Huadong Song Xiaoting Guo +4
0 Citations